Nonlinear characteristics of FY-3D microwave radiation imager and an optimal calculation method

  • role: First author第一作者
  • Affiliation:

    Shanghai Aerospace Electronic Technology Institute, Shanghai 201109, China

  • Email:dslexwpg@163.com
  • Introduction:董克松,1994年生,男,硕士研究生,研究方向为星载微波辐射计系统仿真以及遥感数据应用。E-mail: dslexwpg@163.com
DONG Kesong1,  
  • role: Corresponding author通信作者
  • Affiliation:

    Shanghai Aerospace Electronic Technology Institute, Shanghai 201109, China

  • Email:xinxinxie@ymail.com
  • Introduction:谢鑫新,1984年生,女,高级工程师,研究方向为主动和被动微波遥感。E-mail: xinxinxie@ymail.com
XIE Xinxin1*,  
  • Affiliation:

    Shanghai Aerospace Electronic Technology Institute, Shanghai 201109, China

LI Xue1,  
  • Affiliation:

    Shanghai Academy of Spaceflight Technology, Shanghai 201109, China

LIU Weiliang2

ملخص

The Earth’s radiation was observed by a microwave radiation imager (MWRI) on board FengYun-3D (FY-3D) satellite at 10.65 GHz, 18.7 GHz, 23.8 GHz, 36.5 GHz, and 89.0 GHz with dual polarization. The nonlinearity of this payload, as an important parameter in calibration algorithms, is represented by the nonlinear parameter u from vacuum calibration ground tests. Therefore, an accurate knowledge on the nonlinear characteristics of MWRI is required to achieve precise remote sensing.The nonlinear parameter applied in the calibration algorithm is usually averaged over a set of u, which is calculated at corresponding observed brightness temperatures in the range between 95 K and 298 K. A t-distribution test method is proposed to screen u and further optimize the nonlinearity calculations in this study instead of conventional empirically filtering of u before averaging. The t-method examines the validity of u values at each observed brightness temperatures, and its effectivity is proven in this study.Nonlinear fitting brightness temperatures, as well as means and standard deviation of residual error, were calculated using empirically filtering method and the t-method to demonstrate the results in the nonlinearity calculation. The nonlinear parameter of MWRI is a physical parameter of the instrument, and the nonlinearity of up to 2 K at 10 GHz is mainly introduced by higher-order harmonic during detection. The nonlinear brightness temperature calculated using the t-test distribution method is improved by approximately 0.04 K with better fitting results than the ground tests, especially at 10 GHz.According to the results presented in this study, the nonlinear parameter is independent of observed brightness temperatures, and its nonlinearity is correlated to the instrument’s working condition. The proposed algorithm using the t-test distribution method can improve the nonlinearity fitting results and calibration precision. This method provides accurate nonlinear parameter for on-orbit calibration and can play a role in the total life cycle of MWRI after being launched.

مفهوم

microwave remote sensing;microwave radiation imager;radiometers calibration;nonlinear parameter;nonlinear brightness temperature;t-distribution test method

References

  1. 1.
    An D W, Gu S Y, Yang Z D and Chen W X. 2016. On-orbit radiometric calibration for nonlinear of FY-3C MWTS. Journal of Infrared and Millimeter Waves, 35(3): 317-321
  2. 2.
    Chen W Y, Wang Y, Li X, Xing R X and Liu G F. 2016. The test system, method and results analysis of the vacuum calibration test of microwave radiation imager. Journal of Microwaves, 32(S2): 544-547
  3. 3.
    Fei Y T. 2015. Error Method and Data Processing. 7th ed. Beijing: China Machine Press
  4. 4.
    Hardy W N. 1973. Precision temperature reference for microwave radiometry (Short Papers). IEEE Transactions on Microwave Theory and Techniques, 21(3): 149-150
  5. 5.
    Hollinger J P, Peirce J L and Poe G A. 1990. SSM/I instrument evaluation. IEEE Transactions on Geoscience and Remote Sensing, 28(5): 781-790
  6. 6.
    JPL. 2012. AIRS Project. Algorithm Theoretical Basis Document. Level 1b, Part 3: Microwave Instruments.[s.l.]: JPL
  7. 7.
    Liu G F, Wu S L, Chen W Y, Pan L and He J K. 2014. Calibration system and achievement of microwave radiation imager of FY-3 satellite. Journal of Microwaves, 30(S1): 576-579
  8. 8.
    Liu X. 2009. Design and Application of the Sapceborne Microwave Radiometer. Shanghai: Shanghai Jian Tong University
  9. 9.
    Peng S S and Li X G. 1997. Study on the calibration method of 8mm measuring radiometer. Journal of Infrared and Millimeter Waves, 16(4): 279-284
  10. 10.
    Precipitation Processing System (PPS). 2006. NASA Global Precipitation Measurement Microwave Imager Level 1B Algorithm Theoretical Basis Document Version 2.3. NASA’ s GODDARD Space Flight Center
  11. 11.
    Qiao Mu, Yang Hu, He Jiakai and Lyu Liqing. 2012. On-orbit performanece stability analysis of microwave radiometer imager onboard FY-3 Satellite[J]. Journal of Remote Sensing, 16(6): 1246-1261
  12. 12.
    Ulaby F T, Moore R K and Feng J C. 1988. Microwave Remote Sensing (Volume I) Microwave Remote Sensing Fundamentals and Radiometry. Hou S C and Ma X G, trans. Beijing: Science Press (F T. 乌拉比, RK穆尔, 冯健超. 1988. 微波遥感(第一卷): 微波遥感基础和辐射测量学. 侯世昌, 马锡冠, 译. 北京: 科学出版社)
  13. 13.
    Xiao Z H, Zhang Z Y and Guo W. 2000. A review: the calibration of ground-based, airborne and satellite-borne microwave radiometers. Remote Sensing Technology and Application, 15(2): 113-120
  14. 14.
    Yang H, Weng F Z, Lv L Q, Lu N M, Liu G F, Bai M, Qian Q Y, He J K and Xu H X. 2011. The FengYun-3 microwave radiation imager on-orbit verification. IEEE Transactions on Geoscience and Remote Sensing, 49(11): 4552-4560
  15. 15.
    Ye H. 2012. Calibration and Error Analysis of Microwave Radiometer. Wuhan: Huazhong University of Science and Technology
  16. 16.
    Zhang Miao, Wang Sujuan, Qin Danyu, Qiu Hong and Tang Shihao. 2018. The inversion and quality validation of FY-3C MWRI sea surface temperature [J]. Journal of Remote Sensing, 22(5): 713-722.

قراءة النص الكامل

The above content is generated by Large Model Translation. The translated content is for reference only. We do not assume any commercial or legal responsibilty for any consequences arising from the use of our website