Measurement of Directional Emissivity in Lab Using ltvo-channel and two-temperature Method[J]. Journal of Remote Sensing, 2000, 4(S1): 70. DOI: 10.11834/jrs.2000S111.
Measurement of Directional Emissivity in Lab Using ltvo-channel and two-temperature Method
The active measurement method of emissivity is done by measuring the directional half-sphere reflectance
and it has big errors because of the limited measured points in 2π space and the object heated by the radiative resource.The passive measurement method of emissivity has two problems; it is hard to directly get the temperature of object and difficult to separate the radiance of environment reflected by object from the sensor. In order to avoid measuring the temperature of object and eliminate the radiance of environment
the "box" and "two-temperature" methods have been put forward
but it is impossible to measure directional emissivity. For calculating the radiance of background
we built a boll with more than 3 meter diameter
and in the boll we measured the radiance of aluminum slab in different view angle under two different temperatures using the two-channel sensor attached on automatic frame
then we got directional emissivities of aluminum slab based on the common equation about radiance of background.
State key Laboratory of Remote Sensing Science,Research Center for Remote Sensing&GIS,School of Geography&Remote Sensing,Beijing Normal Uniu.,Beijing 100875,China 2.Environmental Satellite Centre Preparing Office,State Environmental Protection Administration