In-flight absolute radiometric calibration for thermal infrared band of HJ-1B. [J]. Journal of Remote Sensing 14(6):1212-1225(2010) DOI: 10.11834/jrs.20100611.
In-flight absolute radiometric calibration for thermal infrared band of HJ-1B
This paper presentes an in-flight site calibration method for thermal infrared band of HJ-1B
taking advantages of Lake Qinghai test-site for the absolute radiometric calibration for thermal infrared band of HJ-1B.By using measurement data and landsat5-TM to analyze the different results between site calibration and primeval calibration
it shows that the accuracy of in-flight site calibration had been increased 0.6%—3% comparing with the primeval calibration result and the total accuracy is about 1K.Thus this new site calibration method is applicable to the in-flight absolute radiometric calibration of these sensors without the capability of detecting cold space.By the way
the accuracy of calibration for thermal infrared of HJ-1B can meet user’s requirements for the application of quantitative thermal infrared data.
College of Optoelectronics, University of Chinese Academy of Sciences
Chinese Academy of Sciences Key Laboratory of Quantitative Remote Sensing Information Technology, Chinese Academy of Sciences, Aerospace Information Research Institute
Key Laboratory of Quantitative Remote Sensing Information Technology, Institute of Aerospace Information Innovation, Chinese Academy of Sciences