Onboard relative radiation calibration based on deployable solar diffuser

  • role: First author第一作者
  • Affiliation:

    Changguang Satellite Technology CO., LTD. Jilin Key Laboratory of Satellite Remote Sensing Application Technology, Changchun 130000, China

  • Email:wll920707@sina.cn
  • Introduction:1989E-mail wll920707@sina.cn
WANG Lingli1,  
  • Affiliation:

    Changguang Satellite Technology CO., LTD. Jilin Key Laboratory of Satellite Remote Sensing Application Technology, Changchun 130000, China

WU Hongyu1,  
  • role: Corresponding author通信作者
  • Affiliation:

    Changguang Satellite Technology CO., LTD. Jilin Key Laboratory of Satellite Remote Sensing Application Technology, Changchun 130000, China

    Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130000, China

  • Email:baiy776@163.com
  • Introduction:1983E-mail baiy776@163.com
BAI Yang12*,  
  • Affiliation:

    Changguang Satellite Technology CO., LTD. Jilin Key Laboratory of Satellite Remote Sensing Application Technology, Changchun 130000, China

MENG Xiangqiang1,  
  • Affiliation:

    Changguang Satellite Technology CO., LTD. Jilin Key Laboratory of Satellite Remote Sensing Application Technology, Changchun 130000, China

    Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130000, China

HE Xiaojun12,  
  • Affiliation:

    Changguang Satellite Technology CO., LTD. Jilin Key Laboratory of Satellite Remote Sensing Application Technology, Changchun 130000, China

HUANG Shuai1,  
  • Affiliation:

    Changguang Satellite Technology CO., LTD. Jilin Key Laboratory of Satellite Remote Sensing Application Technology, Changchun 130000, China

YANG Song1

résumé

Optical satellite is an important means to obtain remote sensing data by earth observation, and radiation calibration is an important guarantee for quantitative remote sensing. As the satellite sensor is subject to mechanical vibration and acceleration shock during transportation and launch, also taking into account of the aging of optoelectronic devices during long-term on-orbit operation, the radiation performance of the sensor is inevitably affected. As such, the on-orbit radiation calibration is needed to correct the sensor radiation performance. On-orbit calibration is a very important on-orbit calibration method that uses on-satellite calibration devices to measure the radiometric calibration data after the satellite launch. The on-satellite calibrators include calibration lamps, Solar Diffusers (SD) and lunar calibrators, etc. The relative radiometric calibration is used to reduce or eliminate the image high frequency vertical fringe and stripe noise, which are caused by the response difference between detection elements. This process is the premise and foundation of the quantitative application of remote sensing image. In the background of the national major project of global cartography, in order to explore the application potential of relative radiometric calibration for the deployable solar diffuse reflector similar to the Jilin-1 GP satellite, a relative radiometric calibration method based on the solar diffuser is proposed in this paper, which is in order to solve the shortcomings of conventional relative radiometric calibration methods. The method overcomes the dependence of relative radiometric calibration on the accumulation and the uniform consistency of features in the data by imaging through the closing process of the solar diffuse reflector. The solar diffuser is driven by the satellite mechanical structure to close up and adjusts the solar incident energy at the entrance pupil of sensor, by this way acquiring the onboard calibration image. The calibration image covers the whole gray dynamic range of the sensor. Then, the relative radiation calibration coefficients are solved by histogram matching algorithm. In order to verify the method proposed in this paper, the calibration experiment is carried out with the sensor of multispectral spectrometer on JL-1 GP satellite. The correction effect of calibration coefficients on original images are tested and the accuracy of relative radiation calibration is quantitatively analyzed by using non-uniformity. The experimental results show that the calibration coefficients could effectively eliminate the vertical high-frequency fringe and strip noise of the panchromatic and multispectral original image of the ground object. The results of quantitative analysis show that the method proposed in this paper could achieve a good correction effect in the whole dynamic range of sensor’s grayscale, and the relative radiometric calibration accuracy of each band is better than 2%, which fulfills the demand for high-quality remote sensing image applications. On-orbit experiments fully demonstrate that the radiometric calibration method proposed in this paper can complete the calibration task using one solar diffuse reflector closing action, and the proposed method could effectively overcome the dependence of relative radiometric calibration on data accumulation and the uniform consistency of features in the data, which provides a reliable guarantee for quantitative remote sensing applications during the satellite’s on-orbit operation.

mots-clés

deployable solar diffuser;onboard relative radiation calibration;histogram matching;multispectral spectrometer;JL-1 satellite

References

  1. 1.
    Ghani ASA and Isa N A M. 2015. Homomorphic filtering with image fusion for enhancement of details and homogeneous contrast of underwater image. Indian Journal of Geo-Marine Sciences, 44(12): 1904-1919.
  2. 2.
    Guo J N, Yu J, Zeng Y, Xu J Y, Pan Z Q and Hou M H. 2005. Relative radiation correction study of CBERS-01/02 satellite CCD images. Science in China Series E Engineering and Materials Scienc, 32(S1):11-25
  3. 3.
    Huang H L, Yi W N, Qiao Y L and Du L L. 2012. On Orbit Radiometric Calibration for Mapping Satellite-1 Sensor. Journal of Remote Sensing, 16(S1):22-27
  4. 4.
    Huang W X, Zhang L M, Si X L, Cao X J, Li J L, Wang W and Zhu X M. 2017. The Research of On-Orbit Calibration Method Based on Solar Diffuser. Spectroscopy and Spectral Analysis,37(03):952-957
  5. 5.
    Huang W X, Zhang L M, Si X L, Chen H Y, Hao J, Bao S W, Yang B Y and Wang J X. 2020. Influence of Non-uniformity of Light Attenuated by Solar Attenuation Screen on On-board Calibration. Acta Optical Sinica, 40(4): 0429002
  6. 6.
    Jin L B, Wang H, Zhao Y H, Hu B, Shi D L and Lian M L.2020. Design of Expandable Diffuser Board on GF-5 VIMI. Chinese Space Science and Technology, 40(2): 81-87
  7. 7.
    Li H C and Man Y Y.2015. Satellite Attitude Adjustment and Nonlinear Relative Radiometric Calibration Method Based on Linear CCD Imaging the Same Region of Non-uniform Scene. Infrared and Laser Engineering, 44(4): 1370-1376
  8. 8.
    Li X W.2005. Retrospect Prospect and Innovation in Quantitative Remote Sensing. Journal of Henan University(Natural Science), 35(4): 49-56
  9. 9.
    Pesta F, Bhatta S, Helder D L and Mishra N. 2014. Radiometric non-uniformity characterization and correction of Landsat 8 OLI using earth imagery-based techniques. Remote Sensing, 7(1): 430-446
  10. 10.
    Thomas G, Florestapia D and Pistorius S. 2011. Histogram specification: a fast and flexible method to process digital images. IEEE Transactions on Instrumentation and Measurement, 60(5): 1565-1578
  11. 11.
    Wang H. 2019. GF-5 VIMI on-orbit calibration instrument and performance. Journal of Computer and Communications, 7(7): 293-300
  12. 12.
    Wang M, Chen C C, Pan J, Zhu Y and Chang X L. 2018. A relative radiometric calibration method based on the histogram of side-slither data for high-resolution optical satellite imagery. Remote Sensing, 10(3): 381
  13. 13.
    Wang W, Zhang L M, Huang W X, Yang B Y, Wang J X, Xu H Y and Bao S W. 2018. Measurement method of solar attenuation screen characteristic for on-orbit calibration. Acta Optica Sinica, 38(9): 0928001
  14. 14.
    Xu H Y, Zhang L M, Li X, Huang W X, Si X L, Xu W W, Ge S L, Zhao Y H and Wang H. 2020. A relative radiometric calibration method based on solar diffuser research for a linear array CCD detector. Acta Optica Sinica, 40(6): 0628002
  15. 15.
    Zhang Z J, Zhang H, Chang Y G and Chen Z C. 2015.Review of radiometric calibration methods of Landsat series optical remote sensors. Journal of Remote Sensing, 19(5):719-732

Lire l'article complet

The above content is generated by Large Model Translation. The translated content is for reference only. We do not assume any commercial or legal responsibilty for any consequences arising from the use of our website