TANG Xin zhai, ZHANG Ren hua, SU Hong bo, et al. The Sealing cavity Method for Determining Emissivity and Its Deviation Analysis[J]. Journal of Remote Sensing, 2000, (1): 1-7. DOI: 10.11834/jrs.20000101.
The Sealing Cavity method for determining the emissivity of the target object simplified the measuring and computing process. According to above mentioned method
in this paper
the influence on the accurately measuring result of the undulation of target object emittance and environment emittance have been analyzed. Also
we discuss the effect of wavebands between different infrared radiometers. Through lots of experiments
the optimum contrast temperature difference between hot environment and cool environment is given. Finally
three conclusions are drawn to guide the measurement of emissivity.